Lingalaid Septic Systems

How Lingalaid septic tank is made…

The wastewater treatment system offered by Lingalaid OÜ consists of a three-chamber septic tank and the associated suction system accessories. The first chamber of the septic tank forms half, the second and third chambers a quarter of the volume of the septic tank. The quality of our septic tanks is guaranteed thanks to the use of world-renowned raw materials and the initial pressure control of each container already at the semi-finished stage. In accordance with the applicable quality requirements, according to EU standards and regulations of the Ministry of the Environment, the final product is chemically very resistant, weather and temperature resistant and has high mechanical strength.
All Lingalaid septic tanks have a 50-year warranty.

Vahur Poolak

CEO board member

The working principle of a septic system

How does a septic tank work?
In the septic tank, particles heavier than water in the effluent are settled to the bottom of the tank. Following the anaerobic microbiological digestion process at the bottom of the septic tank, the sludge is partially hydrolysed and, after passing through all three chambers of the septic tank, wastewater to the impoundment.
How does the suction field works?
The catchment area is a system of drainage pipes built on the bottom of crushed stone and sand, where the effluent is passed through the crushed stone and the sandy soil layer below it. Such porous soils are an ideal habitat for microorganisms that decompose organic particles into water and carbon dioxide with the help of oxygen from water and aeration.

Septic system 2m3

  • Septic tank 2m3 consist of:

    Three-chamber tank 
    ∅1100mm, length 2200mm, 2000L
    Inlet pipe
    ∅110mm, 1pcs
    Outlet pipe
    ∅110mm, 1pcs
    Service pipe
    ∅400mm, 2pcs
    Pipe cap
    ∅400mm, 2pcs

    The absorbtion field system consists of:

    Pipe branch
    ∅110 mm, 1pcs
    Perforated distribution pipe
    ∅110 mm, length 3000mm, 6pcs
    Coupling sleeve
    ∅110 mm, 6pcs
    Elbow 90°
    ∅110 mm, 2pcs
    Ventilation pipe
    ∅110 mm, length 1000mm, 2pcs
    Ventilation pipe cap
    ∅110 mm, 2pcs
    Geotextile facric
    2000x9000mm, 1pcs

The septic tank with the absorbtion field system is intended for the treatment of sewage and washing water in areas where there is no public sewerage network and natural conditions allow the impregnated water to be impregnated into the soil. The quality of the septic tanks is guaranteed thanks to the use of world-renowned raw materials and the pressure control of each container already at the semi-finished stage.

Following the current quality requirements and regulations of the Ministry of the Environment, the final product is chemically very resistant, weather and temperature resistant and has high mechanical strength.

The septic tanks are in accordance with EN 12566-1: 2000 / A1. The product comes with detailed installation instructions, which also help the professional to do the job quickly and avoid unnecessary expenses.

As a rule, a 2m3 septic tank is suitable for a building with up to five inhabitants.

  • Septic tank 2m3 consist of:

    Three-chamber tank 
    ∅1100mm, length 2200mm, 2000L
    Inlet pipe
    ∅110mm, 1pcs
    Outlet pipe
    ∅110mm, 1pcs
    Service pipe
    ∅400mm, 2pcs
    Pipe cap
    ∅400mm, 2pcs

    The absorbtion field system consists of:

    Pipe branch
    ∅110 mm, 1pcs
    Perforated distribution pipe
    ∅110 mm, length 3000mm, 6pcs
    Coupling sleeve
    ∅110 mm, 6pcs
    Elbow 90°
    ∅110 mm, 2pcs
    Ventilation pipe
    ∅110 mm, length 1000mm, 2pcs
    Ventilation pipe cap
    ∅110 mm, 2pcs
    Geotextile facric
    2000x9000mm, 1pcs

Septic system 3m3

  • Septic tank 3m3 consist of:

    • Three-chamber tank ∅1100mm, length 3300mm, 3000L 
    • Inlet pipe ∅110mm = 1pcs
    • Outlet pipe ∅110mm = 1pcs
    • Service pipe ∅400mm = 3pcs
    • Pipe cap ∅400mm = 3pcs

    The absorption field system consists of:

    • Pipe branch ∅110 mm = 1pcs
    • Perforated distribution pipe ∅110 mm, length 3000mm = 8pcs
    • Coupling sleeve ∅110 mm = 8pcs
    • Elbow 90 ° ∅110 mm = 2pcs
    • Ventilation pipe ∅110 mm, length 1000mm = 2pcs
    • Ventilation pipe cap ∅110 mm = 2pcs
    • Geotextile fabric 2000x12000mm = 1pcs

The septic tank with the absorbtion field system is intended for the treatment of sewage and washing water in areas where there is no public sewerage network and natural conditions allow the impregnated water to be impregnated into the soil. The quality of the septic tanks is guaranteed thanks to the use of world-renowned raw materials and the pressure control of each container already at the semi-finished stage.

Following the current quality requirements and regulations of the Ministry of the Environment, the final product is chemically very resistant, weather and temperature resistant and has high mechanical strength.

The septic tanks are in accordance with EN 12566-1: 2000 / A1. The product comes with detailed installation instructions, which also help the professional to do the job quickly and avoid unnecessary expenses.

The 3m3 septic tank is suitable for households with 6-8 inhabitants.

  • Septic tank 3m3 consist of:

    • Three-chamber tank ∅1100mm, length 3300mm, 3000L 
    • Inlet pipe ∅110mm = 1pcs
    • Outlet pipe ∅110mm = 1pcs
    • Service pipe ∅400mm = 3pcs
    • Pipe cap ∅400mm = 3pcs

    The absorption field system consists of:

    • Pipe branch ∅110 mm = 1pcs
    • Perforated distribution pipe ∅110 mm, length 3000mm = 8pcs
    • Coupling sleeve ∅110 mm = 8pcs
    • Elbow 90 ° ∅110 mm = 2pcs
    • Ventilation pipe ∅110 mm, length 1000mm = 2pcs
    • Ventilation pipe cap ∅110 mm = 2pcs
    • Geotextile fabric 2000x12000mm = 1pcs